+86 0573 86668515
EN  /  CN
TC55M-RJ-1 NON-MID

mV/mA RJ12 Port Current Transformer Input

Measurements: V,A,W,Var,kWh,kVarh,PF, THD...

Bidirectional Energy and Power Measurement

CT Reverse-Connect Correction

Pulse Output

Communication: RS485 Modbus RTU/DLT645-2007

Networks:1P2W/2P3W/3P3W/3P4W

CE/ROHS Approved


Related Suggestion

TC55M-RJ series are designed for the collection and analysis of power parameters and the measurement of energy, multi-circuit three-phase transformer connected to the multi-function energy meter series products, which can support 4 three-phase or 12 single-phase power grid system. It can analyze the most important electrical parameters, including voltage, current, four-quadrant power parameters, power factor, total harmonic, and etc. And it can also read a variety of energy parameters, involving bidirectional active and reactive energy, four-quadrant energy, and so on. The series realizes the measurement and analysis of power parameters in various power grid environments, such as 1P2W, 3P3W and 3P4W.


The TC55M-RJ series have RS485 communication interface with highest baudrate 38400bps, supporting Modbus or DLT645 protocol for remote reading.


At the same time, the large-screen LCD and touch buttons help users to view and set various measurement parameters on site. 

Password protection function is added to greatly improve the data security.


Product Detials
Electrical Specifications
AccuracyVoltage/CurrentClass 0.5, Refer to IEC 61557-12
Active PowerClass 0.5, Refer to IEC 61557-12
Reactive PowerClass 2, Refer to IEC 61557-12
Apparent PowerClass 1, Refer to IEC 61557-12
Active EnergyClass 0.5S, Refer to IEC 62053-21/22, IEC 61557-12
Reactive EnergyClass 2, Refer to IEC 62053-23; Class 2, Refer to IEC 61557-12
Power FactorClass 1, Refer to IEC 61557-12
FrequencyClass 0.2, Refer to IEC 61557-12
Data Upgrading Rate1s (Optional: 100ms)
Voltage InputRated Voltage3x230VAC(L-N)/400VAC(L-L)
Voltage InputMeasurement range: 30 ~ 300 VAC(L-N); 30 ~ 500 VAC(L-L)
PT InputMax. Input:500000 VAC
Loop Impedance1MΩ
Frequency45 ~ 65 Hz
Overload Capacity2x Rated Voltage by lasting 1s
Current InputCT2Fixed: 100mV
CT11 ~ 9999 A
Loop Impedance<0.01 ohm
Overload Capacity20x Max. Current by lasting 0.5s
Aux.Power SupplyVoltage Range80 ~ 300 VAC / 100 ~ 420 VDC
Frequency Range45 ~ 65 Hz
Power Consumption< 4VA/0.5W
Pulse LightPulse constant:5000imp/kWh (Energy of Secondary Side)
Power Consumption ClassSelf-ConsumptionVoltage Circuit: <2W/10VA;
per phaseCurrent Circuit: <1VA




Communication Specifications
Interface and Protocol2-Wire RS485; Modbus RTU(Default), DL/T645-2007(Optional)
Baudrate1200, 2400, 4800, 9600(Default), 19200, 38400 bps
ParityNone(Default), Even, Odd
Stop Bit1(Default), 2
Response Time<100ms
Bus TypeSemi-duplex
DistanceMax. 1000m
Bus LoadMax. 64pcs


Environment Specifications
Operation Temperature-25 ~ +55
Storage Temperature-40 ~ +80
Humidity<90%, no condensing
Pollution Degree2
Altitude<2000m
Vibration FrequencyRange: 10~150Hz, Refer to IEC 60068-2-6


Application Scenario
Our products are widely used in power, energy, industry, construction and many other fields.

Do you have questions about our products?

Please contact us:

Contact

Building 2, No.211, Yanbei Rd, Jiaxing, Zhejiang, China

+86 13706586937(Overseas)

Emily.Zhang@Rayfull.com.cn

15068363717(Chinese Market)

Tyrone.Gu@Rayfull.com.cn

+86 0573 86668515

Copyright © Rayfull Electric Technology(Zhejiang)Co.,Ltd.. All rights reserved.